Capital Controls Single Point Gas Detector provides Continuous detection of chlorine or sulfur dioxide gas in a normally clean air environment.

Gas Detectors are ideal for protection of personnel and property wherever chlorine or sulfur dioxide is uploaded, stored or used.

Highly sensitive, the detector monitors gas levels below OSHA requirements for either chlorine or sulfur dioxide gas.

The sensor responds immediately to the presence of gas, and quickly recovers after the gas has cleared. The sensor is also designed to eliminate false alarms caused by interference gases and environmental conditions.

Series 1610B design includes protection against radio frequency / electro-magnetic interferences (RFI/EMI) typically present at industrial and municipal plants.

The modular design for the gas detector provides easy installation of the receiver and sensor module.

       Single Point Gas Detector Series - 1610B

  • Maintenance-free, long-life sensor
  • Dual alarm output for remote warning and device control Audible and visual alarms
  • Rapid response to chlorine or sulfur dioxide
  • NEMA 4X enclosure
  • Power backup for continuous operation
  • Indicator for remote monitoring
  • RFI/EMI protection

      

Technical Data

Receiver:
Power Requirements : 120 or 240 Vac, 50/60 Hz, single phase
Input from sensor : 4-20 mAdc
Output to sensor : 18-24 Vdc
LED indicators : Power, Ready, Alarm, Malfunction, Bar Graph Indcator
Bar graph indicator range : 0-10 ppm
Indicator signal output : 4-20 mAdc into 900 ohms maximum impedance
Alarm and Malfunction Control Rating : 10 amps @240 Vac maximum or 10 amps @28 Vdc
Enclosure: NEMA 4X (CSA approved available)

Sensor:
Type : Electrochemical of the micro-redox type
Gases sensed: chlorine or sulfur dioxide

Minimum detectable Concentration : 0.5 by volume
Maximum separation between receiver and sensor : 1000 feet (305 meters)


 