Accuracy 0,5 %
4 digit LCD display
Description
Accuracy 0,5 %
4 digit LCD display
Description
Digital pressure gauges provide a digital local indication independent from mains supply.
Their accuracy, reliability and resistance to mechanical load make them suitable for pressure measuring tasks in various applications.
To ensure an easy readout in any installation position the front cover may be rotated up to 350°.
Additionally the display case may be rotated axial-wise by untightening the counter nut at the pressure connection.
The measuring ranges, graded in accordance with EN range from 1 bar up to 400 bar.
The programming of the parameters is done by means of the front keys.
The integrated battery guarantees an operation independent from mains supply.
Optionally a peak value memory, an analoge output or a limit contact can be provided.
The digital pressure gauge meets the electronic magnetic compatibility (EMC) requirements to EN 61 326.
Features
- Ranges from 1 bar up to 400 bar
- l Finely graded selection of pressure ranges
- according to EN
- l LCD display
- l High overload protection
- l Option: peak value memory
- l Option: analoge output
- l Option: limit contacts
Measuring ranges
- Gauge pressure
- negative -1 . . . 0 bar
- positive 0 . . . 1 bar to 0 . . . 400 bar
Applications
- Mechanical engineering,
- Plant and gadgets construction,
- Hydraulics and pneumatics.
Model |
3960 |
Option |
Display
- range
- accuracy
- convertion rate 2 ) |
7-segment LCD-display, 12,7 mm high
9999
0.5% of F. S. 1 )
5/sec. |
|
| Ranges to EN |
0 . . . 1 bar to 0 . . . 400 bar |
1000, 1600 and 2000 bar on request
|
| Pressure type |
positive gauge pressure |
negative gauge pressure |
| Overload limit |
² 40 bar 3-fold
³ 60 bar 2-fold
³ 250 bar 1,5-fold |
|
| Wetted parts |
stainless steel 1.4571; Al 2 O 3 ; NBR |
|
| Pressure connection |
G 1/4 A |
others on request |
Programmable parameter
- zero point adjustment |
² ± 25% of F. S. |
|
Power supply
- battery life
- autom. switch off 3 ) |
9 V monoblock battery
5000h (600 mAh)
10000h (1200 mAh)
2 . . . 90 min. (factory set) |
|
Temperature comp. range |
0 . . . 60 °C |
|
Temperature influence
- zero point
- span |
² ± 0.2%/10 K
² ± 0.1%/10 K |
|
Protection type
- max. rel. humidity |
IP 65 accord. EN 60 529/IEC 529
< 90%, non condensating |
|
Emission 4 ) |
to EN 61 326 |
|
Interference 4 ) |
to EN 61 326 |
|
Electrical protection types |
reverse polarity protection |
|
Temperature ranges
- storage
- media
- ambient |
-30 . . . 80 °C
-30 . . . 85 °C
0 . . . 60 °C |
|
Case |
Plastic |
|
Weight |
approx. 0.4 kg |
|
1 ) Terminal point adjustment according to DIN 16 086 incl. linearity and hysteresis. of F. S. = of full scale value
2 ) Factory set between 1 to 10 / sec.
3 ) Not available for options analog output or limit contact.
4 ) Declaration for conformity on request.
Options 5 )
|
Peak value memory
- programmable |
as MIN- or MAX-value memory |
|
Analoge output
• load
• electr. connection |
0 . . . 2 VDC
³ 100 k ½
round connector M12x1, 5-pin or cable outlet, 0.5 m cable |
|
Limit contact Relay
-switching function
-contact rating
-adjustability switching point and
-electr. connection |
Output
NO
30 VAC/DC, 2A
switching point and hysteresis freely programmable
round connector M12x1, 5-pin or cable outlet, 0.5 m cable |